Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 827
Filtrar
1.
J. optom. (Internet) ; 17(3): [100514], jul.-sept2024. tab
Artigo em Inglês | IBECS | ID: ibc-231876

RESUMO

Purpose: To analyze binocular vision of individuals aged 18 to 35 years diagnosed with keratoconus, utilizing spectacles and rigid gas-permeable (RGP) contact lenses. Research was led by the Universidad Autónoma de Aguascalientes, México and Fundación Universitaria del Área Andina Pereira, Colombia. Methods: A single center, prospective non-randomized, comparative, interventional, open-label study, in which the differences in binocular vision performance with both spectacles and RGP contact lenses was carried out from December 2018 to December 2019. Sampling was performed according to consecutive cases with keratoconus that met the inclusion criteria until the proposed sample size was reached. Results: Rigid gas-permeable (RGP) contact lenses notably enhanced distance and near visual acuity in keratoconus patients compared to spectacles. Visual alignment analysis shows exophoria at both distances and is slightly higher with RGP contact lenses. The difference was statistically significant (p<0.05), with 82.5 % presenting compensated phoria with spectacles and pnly 42.50% with RGP contact lenses. Stereoscopic vision improved while wearing RGP contact lenses (42.59 %), although accommodation and accommodative flexibility remained within normal ranges. Conclusions: Patients with keratoconus fitted with RGP contact lenses have improved binocular vision skills such as visual acuity, stereopsis, and accommodative flexibility. However, even when the vergence and motor system is decompensated with respect to normal ranges, the range between break and recovery points for both fusional reserves and the near point of convergence (NPC) improves with the use of RGP contact lenses, giving indications of an adaptive condition of the motor system from the medium to the long term.(AU)


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto Jovem , Ceratocone , Óculos , Lentes de Contato , Visão Binocular , Testes Visuais , Colômbia , México , Oftalmologia , Estudos Prospectivos
2.
Clin Optom (Auckl) ; 16: 93-100, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38559802

RESUMO

Introduction: Patients expect to have excellent vision and comfort when wearing soft contact lenses. The purpose of this study was to compare the wear experiences of participants with astigmatism when wearing a daily disposable soft toric lens to an established, commonly used reusable toric lens. Methods: In this crossover study, habitual soft toric lens wearers were fit with a daily replacement soft toric lens (delefilcon A) and a reusable, 1-month replacement soft toric lens (comfilcon A) in a randomized order. After 30 days of wear, Visual analog scale (VAS) surveys were used to assess wear experience, including vision and comfort, for overall wear and end-of-day wear. Scores were compared statistically with mixed-effects linear models. Participants also responded to questions about convenience, ease of use, and satisfaction with both lenses and preference questions based upon comfort, vision, and overall performance. Results: Fifty-nine participants completed the multi-site crossover study. VAS scores [mean(std dev)] for overall quality of vision for the delefilcon A [80.4(16.4)] and comfilcon A [66.8(27.7)] lenses were statistically significant (P=0.002). The difference in the mean overall comfort scores for the delefilcon A lenses [71.6(26.3)] and comfilcon A lenses [63.2(28.9)] was 8.4, which exceeds the establish criteria for clinical significance, although not statistically significant (P=0.08). Overall satisfaction scores were 68.8(26.9) for the delefilcon A and 59.7(30.3) for the comfilcon A lenses (P=0.08). Both lenses provided mean binocular visual acuities better than 20/20 Snellen equivalent. Over half of the participants preferred the delefilcon A lenses based upon comfort, vision, and overall performance. Convenience, ease of use, and satisfaction all scored higher with delefilcon A lenses. Conclusion: The results of this study show that wear experience with delefilcon A lenses for astigmatism can meet or exceed that of comfilcon A toric lenses while also providing healthy, daily disposable lens wear.

3.
Artigo em Inglês | MEDLINE | ID: mdl-38578134

RESUMO

PURPOSE: To investigate gaze and behavioural metrics at different viewing distances with multifocal contact lenses (MFCLs), single vision contact lenses (SVCLs) and progressive addition lenses (PALs). METHODS: Fifteen presbyopic contact lens wearers participated over five separate study visits. At each visit, participants were randomly assigned to wear one of five refractive corrections: habitual PAL spectacles, delefilcon A (Alcon Inc.) MFCLs and three separate pairs of delefilcon A single vision lenses worn as distance, intermediate and near corrections. Participants wore a Pupil Core headset to record eye and head movements while performing three visual tasks: reading, visual search and scene observation. Data were investigated using linear regression and post-hoc testing. Parameters of interest included gaze (fixation duration, head movement) and behavioural (reading speed, reading accuracy, visual search time) metrics. RESULTS: Reading speed in SVCLs was significantly faster than in MFCLs and PAL spectacles (F = 16.3, p < 0.0001). Refractive correction worn did not influence visual search times (F = 0.16, p = 0.85). Fixation duration was significantly affected by the type of visual task (F = 60.2, p < 0.001), and an interaction effect was observed between viewing distance and refractive correction (F = 4.3, p = 0.002). There was significantly more horizontal and vertical head movement (F = 3.2, p = 0.01 and F = 3.3, p = 0.01, respectively) during visual search tasks when wearing PAL spectacles compared to SVCLs or MFCLs. CONCLUSION: This work showed that the type of refractive correction affects behavioural metrics such as reading speed and gaze behaviour by affecting horizontal and vertical head movements. The findings of this study suggest that under certain conditions, wearers of MFCLs make fewer head movements compared to PAL spectacles. Gaze behaviour metrics offer a new approach to compare and understand contact lens and spectacle performance, with potential applications including peripheral optical designs for myopia management.

4.
Adv Mater ; : e2313848, 2024 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-38583064

RESUMO

The increasing prevalence of dry eye syndrome in aging and digital societies compromises long-term contact lens (CL) wear and forces users to regular eye drop instillation to alleviate discomfort. Here a novel approach with the potential to improve and extend the lubrication properties of CLs is presented. This is achieved by embedding lubricant-secreting biofactories within the CL material. The self-replenishable reservoirs autonomously produce and release hyaluronic acid (HA), a natural lubrication and wetting agent, long term. The hydrogel matrix regulates the growth of the biofactories and the HA production, and allows the diffusion of nutrients and HA for at least 3 weeks. The continuous release of HA sustainably reduces the friction coefficient of the CL surface. A self-lubricating CL prototype is presented, where the functional biofactories are contained in a functional ring at the lens periphery, outside of the vision area. The device is cytocompatible and fulfils physicochemical requirements of commercial CLs. The fabrication process is compatible with current manufacturing processes of CLs for vision correction. It is envisioned that the durable-by-design approach in living CL could enable long-term wear comfort for CL users and minimize the need for lubricating eye drops.

5.
Cont Lens Anterior Eye ; : 102160, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38570253

RESUMO

PURPOSE: To investigate the differences in contact lens sagittal depth (CL-SAG), base curve (BC), and overall lens diameter (OAD) of daily disposable (DD) SCLs at room temperature (20 °C) and on-eye (34 °C) temperature. METHODS: Twelve different spherical daily SCLs were analyzed (labeled power -3.00 D) at 20 °C and 34 °C. The posterior CL-SAG, BC, and OAD were measured directly using a spectral domain OCT-based instrument (Optimec is830). RESULTS: The CL-SAG range for the daily disposable lenses measured at 20 °C was 3468-4016 µm. At 34 °C, the DD CL-SAG of all lenses individually decreased compared to 20 °C (t = 7.78, p < 0.001), ranging from 3385 to 3913 µm. On average at the higher temperature, the measured overall lens diameter was smaller (t = 8.18, p < 0.001) and the BC was marginally steeper (t = 2.11, p = 0.058). CONCLUSIONS: Soft lens parameters change when equilibrated from room temperature (20 °C) to on-eye temperature (34 °C). All lenses shrink when going to on-eye temperature (both lens diameter and CL-SAG decreases), compared to lenses measured at room temperature by ISO standards. Higher water content materials tend to have greater changes to the lens parameters compared to lower water content material lenses.

6.
Artigo em Inglês | MEDLINE | ID: mdl-38588998

RESUMO

This 32-centre multicentre study addresses the lack of knowledge about the prevalence and significance of microbial keratitis (MK) associated with contact lens (CL) wear in Spain. A total of 304 cases recruited from 32 hospitals were studied and showed that infectious keratitis associated with contact lens wear mainly affects young women during the summer months. In this study, soft lenses with monthly replacement and single solution cleaning were most commonly used, purchased and fitted in opticians' shops. Common risk factors were identified among users, such as topping off solutions, prolonging the life of lenses, and frequently sleeping, swimming and showering with lenses. Overnight lens wear was significantly associated with a higher incidence of corneal opacities, and the presence of Pseudomonas aeruginosa in bacterial cultures was associated with more severe sequelae and a greater need for corneal transplantation. Although most cases were benign, the time taken to heal was long, which poses a problem for working patients. This study provides valuable epidemiological, microbiological and risk factor information and estimates the incidence of CL related MK in Spain to be approximately 1 case per 30,000 inhabitants per year.

7.
Cont Lens Anterior Eye ; : 102158, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38631935

RESUMO

This paper seeks to outline the history, market situation, clinical management and product performance related to the correction of presbyopia with both contact lenses and spectacles. The history of the development of various optical forms of presbyopic correction are reviewed, and an overview is presented of the current market status of contact lenses and spectacles. Clinical considerations in the fitting and aftercare of presbyopic contact lens and spectacle lens wearers are presented, with general recommendations for best practice. Current options for contact lens correction of presbyopia include soft simultaneous, rigid translating and rigid simultaneous designs, in addition to monovision. Spectacle options include single vision lenses, bifocal lenses and a range of progressive addition lenses. The comparative performance of both contact lens and spectacle lens options is presented. With a significant proportion of the global population now being presbyopic, this overview is particularly timely and is designed to act as a guide for researchers, industry and eyecare practitioners alike.

8.
Biosens Bioelectron ; 257: 116284, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38657379

RESUMO

Smart contact lenses (SCLs) have been considered as novel wearable devices for out-of-hospital and self-monitoring applications. They are capable of non-invasively and continuously monitoring physiological signals in the eyes, including vital biophysical (e.g., intraocular of pressure, temperature, and electrophysiological signal) and biochemical signals (e.g., pH, glucose, protein, nitrite, lactic acid, and ions). Recent progress mainly focuses on the rational design of wearable SCLs for physiological signal monitoring, while also facilitating the treatment of various ocular diseases. It covers contact lens materials, fabrication technologies, and integration methods. We also highlight and discuss a critical comparison of SCLs with electrical, microfluidic, and optical signal outputs in health monitoring. Their advantages and disadvantages could help researchers to make decisions when developing SCLs with desired properties for physiological signal monitoring. These unique capabilities make SCLs promising diagnostic and therapeutic tools. Despite the extensive research in SCLs, new technologies are still in their early stages of development and there are a few challenges to be addressed before these SCLs technologies can be successfully commercialized particularly in the form of rigorous clinical trials.

9.
Ther Adv Ophthalmol ; 16: 25158414241232258, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38516169

RESUMO

Background: New developments in artificial intelligence, particularly with promising results in early detection and management of keratoconus, have favorably altered the natural history of the disease over the last few decades. Features of artificial intelligence in different machine such as anterior segment optical coherence tomography, and femtosecond laser technique have improved safety, precision, effectiveness, and predictability of treatment modalities of keratoconus (from contact lenses to keratoplasty techniques). These options ingrained in artificial intelligence are already underway and allow ophthalmologist to approach disease in the most non-invasive way. Objectives: This study comprehensively describes all of the treatment modalities of keratoconus considering machine learning strategies. Design: A multidimensional comprehensive systematic narrative review. Data sources and methods: A comprehensive search was done in the five main electronic databases (PubMed, Scopus, Web of Science, Embase, and Cochrane), without language and time or type of study restrictions. Afterward, eligible articles were selected by screening the titles and abstracts based on main mesh keywords. For potentially eligible articles, the full text was also reviewed. Results: Artificial intelligence demonstrates promise in keratoconus diagnosis and clinical management, spanning early detection (especially in subclinical cases), preoperative screening, postoperative ectasia prediction after keratorefractive surgery, and guiding surgical decisions. The majority of studies employed a solitary machine learning algorithm, whereas minor studies assessed multiple algorithms that evaluated the association of various keratoconus staging and management strategies. Last but not least, AI has proven effective in guiding the implantation of intracorneal ring segments in keratoconus corneas and predicting surgical outcomes. Conclusion: The efficient and widespread clinical translation of machine learning models in keratoconus management is a crucial goal of potential future approaches to better visual performance in keratoconus patients. Trial registration: The article has been registered through PROSPERO, an international database of prospectively registered systematic reviews, with the ID: CRD42022319338.


Keratoconus: from fundamentals to future Artificial intelligence has changed how we treat the eye disease keratoconus in recent years. This study examines the many keratoconus therapies available, including surgery and contact lens wear, and how artificial intelligence can improve the safety and accuracy of these procedures. We combed through numerous papers to locate this data. To achieve the best outcomes, several parameters and methods should be evaluated. According to the study, some elements from eye scans are more useful than others. The idea behind using artificial intelligence is to help patients see better and treat keratoconus more effectively.

10.
J Control Release ; 369: 114-127, 2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38521167

RESUMO

This research introduces an innovative solution to address the challenges of bacterial keratitis and alkali burns. Current treatments for bacterial keratitis and alkali burns rely on the frequent use of antibiotics and anti-inflammatory eye drops. However, these approaches suffer from poor bioavailability and fluctuating concentrations, leading to limited efficacy and potential drug resistance. Our approach presents an adaptive drug-releasing contact lens responsive to reactive oxygen species (ROS) at ocular inflammation sites, synchronously releasing Levofloxacin and Diclofenac. During storage, minimal drug release occurred, but over 7 days of wear, the lens maintained a continuous, customizable drug release rate based on disease severity. This contact lens had strong antibacterial activity and biofilm prevention, effectively treating bacterial keratitis. When combined with autologous serum, this hydrophilic, flexible lens aids corneal epithelial regeneration, reducing irritation and promoting healing. In summary, this ROS-responsive drug-releasing contact lens combines antibacterial and anti-inflammatory effects, offering a promising solution for bacterial keratitis and alkali burns.

11.
Eur J Ophthalmol ; : 11206721241242165, 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38509758

RESUMO

PURPOSE: The purpose of this paper is to report the increasing incidence of contact-lens related Acanthamoeba keratitis (AK) in a tertiary ophthalmology department in Umbria, central Italy. METHODS: Observational and retrospective case series were carried out. A total of nine eyes with a diagnosis of AK were examined. All patients underwent a full slit lamp examination, in vivo confocal microscopy (IVCM) and corneal scraping. The IVCM was repeated at one and two-week and at one, three and six-month intervals. Samples of domestic tap water were also examined for PCR analysis. Patients were treated with levofloxacin0,5%, Polyhexamethylene biguanide 0.02%, and Propamidine Isetionate0,1%. RESULTS: All patients were contact lens wearers. The average patient age was 27.75 (range 18-45), with three men and five women. The main clinical features were ciliary congestion, diffuse epitheliopathy with punctuated keratitis, multiple, small sub-epithelial, greyish, corneal infiltrates with epithelial defect, pseudodendritic corneal lesions, perineural infiltrates, corneal stromal cellularity, and stromal infiltrates. IVCM was indicative of Acanthamoeba in seven out of the nine eyes. All the positive IVCM images were section images showing double walled, bright-spot cysts with a clear chain-like arrangement of five or more cysts identified in three of the patients. PCR analysis of the water was negative in all cases. CONCLUSION: Although PCR is the most common method used, the increased incidence of AK could mainly be related to a proper IVCM interpretation. A broad-spectrum antibiotic, such as levofloxacin might play a role in the early treatment of AK reducing the virulence of the amoeba.

12.
Vision (Basel) ; 8(1)2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38535760

RESUMO

This prospective, double-masked, contralateral study aimed to analyze and compare daytime changes in pre-lens tear film (PLTF) stability and optical quality in symptomatic subjects wearing two contact lenses (CL). A secondary goal was to assess the performance of the PLTF by using dynamic topography techniques and analyzing surface asymmetry and irregularity indexes (SAI and SRI, respectively). Measurements were conducted on 20 symptomatic subjects (OSDI score > 13). Participants were fitted contralaterally and randomly with spherical Delefilcon A and Stenfilcon A CLs and underwent a series of measurements over 3 consecutive days: three in the morning (after 1-2 h of CL wear) and three in the afternoon (after 7-9 h of CL wear). High- and low-contrast visual acuity (HCVA and LCVA, respectively), pre-lens NIBUT, and dynamic topography were assessed. The contralateral fit of the two lenses allowed a direct and better comparison between them since they were exposed to the same conditions during the day. Consequently, both lenses demonstrated similar performance in HCVA, LCVA, and PLTF stability, with no statistically significant differences between them, although some fluctuations were observed throughout the day. Dynamic topography proved sensitive in evaluating temporal changes in the PLTF. The SRI index showed greater sensitivity to topographic changes due to lacrimal destabilization, making it potentially valuable for evaluating dry eye patients.

13.
Artigo em Inglês | MEDLINE | ID: mdl-38525850

RESUMO

PURPOSE: This study addressed the utilisation of machine learning techniques to estimate tear osmolarity, a clinically significant yet challenging parameter to measure accurately. Elevated tear osmolarity has been observed in contact lens wearers and is associated with contact lens-induced dry eye, a common cause of discomfort leading to discontinuation of lens wear. METHODS: The study explored machine learning, regression and classification techniques to predict tear osmolarity using routine clinical parameters. The data set consisted of 175 participants, primarily healthy subjects eligible for soft contact lens wear. Various clinical assessments were performed, including symptom assessment with the Ocular Surface Disease Index and 5-Item Dry Eye Questionnaire (DEQ-5), tear meniscus height (TMH), tear osmolarity, non-invasive keratometric tear film break-up time (NIKBUT), ocular redness, corneal and conjunctival fluorescein staining and Meibomian glands loss. RESULTS: The results revealed that simple linear regression was insufficient for accurate osmolarity prediction. Instead, more advanced regression models achieved a moderate level of predictive power, explaining approximately 32% of the osmolarity variability. Notably, key predictors for osmolarity included NIKBUT, TMH, ocular redness, Meibomian gland coverage and the DEQ-5 questionnaire. In classification tasks, distinguishing between low (<299 mOsmol/L), medium (300-307 mOsmol/L) and high osmolarity (>308 mOsmol/L) levels yielded an accuracy of approximately 80%. Key parameters for classification were similar to those in regression models, emphasising the importance of NIKBUT, TMH, ocular redness, Meibomian glands coverage and the DEQ-5 questionnaire. CONCLUSIONS: This study highlights the potential benefits of integrating machine learning into contact lens research and practice. It suggests the clinical utility of assessing Meibomian glands and NIKBUT in contact lens fitting and follow-up visits. Machine learning models can optimise contact lens prescriptions and aid in early detection of conditions like dry eye, ultimately enhancing ocular health and the contact lens wearing experience.

14.
Cont Lens Anterior Eye ; 47(2): 102130, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38443210

RESUMO

INTRODUCTION: Artificial Intelligence (AI) chatbots are able to explain complex concepts using plain language. The aim of this study was to assess the accuracy of three AI chatbots answering common questions related to contact lens (CL) wear. METHODS: Three open access AI chatbots were compared: Perplexity, Open Assistant and ChatGPT 3.5. Ten general CL questions were asked to all AI chatbots on the same day in two different countries, with the questions asked in Spanish from Spain and in English from the U.K. Two independent optometrists with experience working in each country assessed the accuracy of the answers provided. Also, the AI chatbots' responses were assessed if their outputs showed any bias towards (or against) any eye care professional (ECP). RESULTS: The answers obtained by the same AI chatbots were different in Spain and the U.K. Also, statistically significant differences were found between the AI chatbots for accuracy. In the U.K., ChatGPT 3.5 was the most and Open Assistant least accurate (p < 0.01). In Spain, Perplexity and ChatGPT were statistically more accurate than Open Assistant (p < 0.01). All the AI chatbots presented bias, except ChatGPT 3.5 in Spain. CONCLUSIONS: AI chatbots do not always consider local CL legislation, and their accuracy seems to be dependent on the language used to interact with them. Hence, at this time, although some AI chatbots might be a good source of information for general CL related questions, they cannot replace an ECP.


Assuntos
Lentes de Contato , Optometristas , Humanos , Inteligência Artificial , Idioma , Fonte de Informação
15.
J. optom. (Internet) ; 17(1)Jan.-March. 2024. tab, graf
Artigo em Inglês | IBECS | ID: ibc-229115

RESUMO

Objective This study analyses strategies and attitudes on myopia management reported by eye care practitioners (ECP) from Spain in 2022. Methods A questionnaire was distributed to ECPs worldwide via the internet through professional associations. The questionnaire was distributed by email to all registered Spanish optician-optometrists. Questions examined awareness of increasing myopia prevalence; perceived efficacy; uptake of available approaches; and reasons preventing further uptake of specific approaches. Results Of 3,107 practitioners who participated in the study, 380 were Spanish ECPs. Using a 10-point scale, Spanish practitioners reported less concern about increasing pediatric myopia (8.3 ± 1.6) compared to ECP's worldwide (8.5 ± 1.9) (p < 0.001), but similar level of clinical activity in myopia control (7.8 ± 2.3 vs. 7.5 ± 2.5, respectively) (p > 0.05); however, around half of all prescribed treatments were single-vision distance spectacles/contact lenses both in Spain and in most regions, with Spanish practitioners prescribing less single-vision spectacles than African and Asian (p < 0.001), but more than Australasian practitioners (p = 0.04). No significant differences were found between Spain and the other regions in the perceived efficacy of combined therapy, orthokeratology, and outdoor time (p > 0.05), with the former being perceived as the most effective myopia control method followed by orthokeratology. No significant differences were found between Spain and the world's average in factors preventing the prescription of myopia control approaches (p > 0.05). Spanish practitioners reported that embracing myopia management has a positive, but lower impact on customer loyalty, practice revenue and job satisfaction compared with the other regions (all p < 0.001). Conclusions Myopia control is increasing, although around half of practitioners still prescribe single-vision distance spectacles/contact lenses to. ... . (AU)


Assuntos
Humanos , Miopia/prevenção & controle , Miopia/terapia , Lentes de Contato , Óculos , Espanha
16.
Clin Proteomics ; 21(1): 23, 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38481131

RESUMO

BACKGROUND: Human tear protein biomarkers are useful for detecting ocular and systemic diseases. Unfortunately, existing tear film sampling methods (Schirmer strip; SS and microcapillary tube; MCT) have significant drawbacks, such as pain, risk of injury, sampling difficulty, and proteomic disparities between methods. Here, we present an alternative tear protein sampling method using soft contact lenses (SCLs). RESULTS: We optimized the SCL protein sampling in vitro and performed in vivo studies in 6 subjects. Using Etafilcon A SCLs and 4M guanidine-HCl for protein removal, we sampled an average of 60 ± 31 µg of protein per eye. We also performed objective and subjective assessments of all sampling methods. Signs of irritation post-sampling were observed with SS but not with MCT and SCLs. Proteomic analysis by mass spectrometry (MS) revealed that all sampling methods resulted in the detection of abundant tear proteins. However, smaller subsets of unique and shared proteins were identified, particularly for SS and MCT. Additionally, there was no significant intrasubject variation between MCT and SCL sampling. CONCLUSIONS: These experiments demonstrate that SCLs are an accessible tear-sampling method with the potential to surpass current methods in sampling basal tears.

17.
Cont Lens Anterior Eye ; : 102137, 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38485618

RESUMO

A common non-spectacle strategy to correct presbyopia is to provide simultaneous images with multifocal optical designs. Understanding the neuroadaptation mechanisms behind multifocal devices usage would have important clinical implications, such as predicting whether patients will be able to tolerate multifocal optics. The aim of this study was to evaluate the brain correlates during the initial wear of multifocal contact lenses (CLs) using high-density visual evoked potential (VEP) measures. Fifteen presbyopes (mean age 51.8 ±â€¯2.6 years) who had previously not used multifocal CLs were enrolled. VEP measures were achieved while participants looked at arrays of 0.5 logMAR Sloan letters in three different optical conditions arranged with CLs: monofocal condition with the optical power appropriate for the distance viewing; multifocal correction with medium addition; and multifocal correction with low addition. An ANOVA for repeated measures showed that the amplitude of the C1 and N1 components significantly dropped with both multifocal low and medium addition CL conditions compared to monofocal CLs. The P1 and P2 components showed opposite behavior with an increase in amplitudes for multifocal compared to monofocal conditions. VEP data indicated that multifocal presbyopia corrections produce a loss of feedforward activity in the primary visual cortex that is compensated by extra feedback activity in extrastriate areas only, in both early and late visual processing.

18.
Small ; : e2401068, 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38477701

RESUMO

On-the-eye microsystems such as smart contacts for vision correction, health monitoring, drug delivery, and displaying information represent a new emerging class of low-profile (≤ 1 mm) wireless microsystems that conform to the curvature of the eyeball surface. The implementation of suitable low-profile power sources for eye-based microsystems on curved substrates is a major technical challenge addressed in this paper. The fabrication and characterization of a hybrid energy generation unit composed of a flexible silicon solar cell and eye-blinking activated Mg-O2 metal-air harvester capable of sustainably supplying electrical power to smart ocular devices are reported. The encapsulated photovoltaic device provides a DC output with a power density of 42.4 µW cm-2 and 2.5 mW cm-2 under indoor and outdoor lighting conditions, respectively. The eye-blinking activated Mg-air harvester delivers pulsed power output with a maximum power density of 1.3 mW cm-2 . A power management circuit with an integrated 11 mF supercapacitor is used to convert the harvesters' pulsed voltages to DC, boost up the voltages, and continuously deliver ≈150 µW at a stable 3.3 V DC output. Uniquely, in contrast to wireless power transfer, the power pack continuously generates electric power and does not require any type of external accessories for operation.

19.
Int J Mol Sci ; 25(5)2024 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-38473902

RESUMO

The increase in bacterial resistance to antibiotics in recent years demands innovative strategies for the detection and combating of biofilms, which are notoriously resilient. Biofilms, particularly those on contact lenses, can lead to biofilm-related infections (e.g., conjunctivitis and keratitis), posing a significant risk to patients. Non-destructive and non-contact sensing techniques are essential in addressing this threat. Digital holographic tomography emerges as a promising solution. This allows for the 3D reconstruction of the refractive index distribution in biological samples, enabling label-free visualization and the quantitative analysis of biofilms. This tool provides insight into the dynamics of biofilm formation and maturation on the surface of transparent materials. Applying digital holographic tomography for biofilm examination has the potential to advance our ability to combat the antibiotic bacterial resistance crisis. A recent study focused on characterizing biofilm formation and maturation on six soft contact lens materials (three silicone hydrogels, three hydrogels), with a particular emphasis on Staphylococcus epidermis and Pseudomonas aeruginosa, both common culprits in ocular infections. The results revealed species- and time-dependent variations in the refractive indexes and volumes of biofilms, shedding light on cell dynamics, cell death, and contact lens material-related factors. The use of digital holographic tomography enables the quantitative analysis of biofilm dynamics, providing us with a better understanding and characterization of bacterial biofilms.


Assuntos
Biofilmes , Lentes de Contato Hidrofílicas , Humanos , Bactérias , Antibacterianos , Hidrogéis , Lentes de Contato Hidrofílicas/microbiologia , Pseudomonas aeruginosa/fisiologia
20.
J Ocul Pharmacol Ther ; 40(3): 160-172, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38394222

RESUMO

Fungal keratitis (FK) is a dangerous corneal infection that is common in tropical and subtropical areas. Its incidence is extremely high, and ocular trauma and contact lenses can lead to FK, but its common treatment such as using topical antifungal eye drop instillation is often less effective because of several drawbacks of the drugs typically used, including limited ocular penetration, high frequency of dosing, poor biocompatibility, and the potential for severe drug reactions. Therefore, the development of novel drug delivery devices for the treatment of FK is urgent. The urgent need for novel drug delivery devices to treat FK has led to the development of several techniques, including nanoparticles (NPs), in situ forming hydrogels, contact lenses, and microneedles (MNs). However, it is important to note that the main mechanisms differ between these techniques. NPs can transport large amounts of drugs and be taken up by cells owing to their large surface area and small size. In situ forming hydrogels can significantly extend the residence time of drugs because of their strong adhesive properties. Contact lenses, with their comfortable shape and drug-carrying capacity, can also act as drug delivery devices. MNs can create channels in the cornea, bypassing its barrier and enhancing drug bioavailability. This article will go over novel medication delivery techniques for treating FK and make a conclusion about their advantages and limitations in anticipation to serve the best option for the individual therapy of FK.


Assuntos
Úlcera da Córnea , Infecções Oculares Fúngicas , Ceratite , Humanos , Úlcera da Córnea/tratamento farmacológico , Sistemas de Liberação de Medicamentos/métodos , Ceratite/tratamento farmacológico , Ceratite/microbiologia , Infecções Oculares Fúngicas/tratamento farmacológico , Infecções Oculares Fúngicas/microbiologia , Hidrogéis
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...